1. D-300 (5V Model)
D-300(LG) series is the smallest Dual CO2 sensor module in the world. Its Persistent Stability and Temperature Effect Resistance are much favored in warehouse, greenhouse, hospitals etc. besides the small size and consistent accuracy through the life cycle.
General Performance
Operating Temperature : -20 ~ 50℃
Operating Humidity : 0 ~ 95% RH (Non-condensing),
'G' option 0 ~ 99% RH (Non-condensing)
Operating Environment : HVAC in Hospital, Warehouse, Greenhouse
Storage Temperature : -30℃ ~ 70℃
CO₂ Measurement
Sensing Method : NDIR (Non-dispersive Infrared)
Measurement Range : 0 ~ 2,000(3,000/5,000/10,000ppm, 2%/3%/5% models are available)
Accuracy : ±30ppm ±3% of reading (±300ppm ±3% of reading - 2%/3%/5% models)
Response Time (1/e) : 90 seconds
Sampling Interval : 3 seconds
Electrical Data
Power Input : 5V ± 5%
Current Consumption : Normal mode : 25mA, Peak : 250mA, Sleep < 0.5 mA
Product Derivatives with Functions
| Products |
Feature |
|
| D-300 |
UART,I2C, ALARM, AVO/PWM option, ‘0/400’ppm MCDL |
|
| D-300L |
Sleep mode is added on D-300 for Low Power, which consume < 0.5mA |
|
| D-300G |
Resistant up to 99% Humidity for Application of Agricultural Green House, Stock Raising,etc |
|
| D-300LG |
Sleep mode + 99% Humidity |
|
2. D-300-3V (3V Model)
D-300(LG)-3V series is the smallest
Dual CO2 sensor module in the world. Its Persistent Stability and Temperature Effect Resistance are welcomed as HVAC in warehouse, greenhouse, hospitals etc. D-300(LG)-3V is much favored by customers whose application needs 3.3Voltage input and sleep mode support so on.
General Performance
Operating Temperature : -20 ~ 50℃
Operating Humidity : 0 ~ 95% RH (Non-condensing),
'G' option
0 ~ 99% RH (Non-condensing)
Operating Environment : HVAC in Hospital, Warehouse, Greenhouse
Storage Temperature : -30℃ ~ 70℃
CO₂ Measurement
Sensing Method : NDIR (Non-dispersive Infrared)
Measurement Range : 0 ~ 2,000(3,000/5,000/10,000ppm, 2%/3%/5% models are available)
Accuracy : ±30ppm ±3% of reading (±300ppm ±3% of reading - 2%/3%/5% models)
Response Time (1/e) : 90 seconds
Sampling Interval : 3 seconds
Electrical Data
Power Input : 3.2V ~ 3.6V
Current Consumption : Normal mode : 12mA, Peak : 180mA, Sleep < 0.3 mA
Product Derivatives with Functions
| Products |
Feature |
| D-300-3V |
UART,I2C, ALARM, (AVO or PWM option), ‘0/400’ppm MCDL |
| D-300L-3V |
Sleep mode is added on D-300 for Low Power, which consume < 0.3mA |
| D-300G-3V |
Resistant up to 99% Humidity for Application of Green House |
| D-300LG-3V |
Sleep mode + 99% Humidity |